Smart Calculators SmartCalculators

Roof Pitch Calculator

Find a roof's pitch from a level reading, the ridge height or a known angle, with rafter length, roof area, and which roof coverings the code allows at that pitch.

Slope

How do you know the slope?

Same unit for both, e.g. inches of rise over a 12-inch level

Roof

Roof type
ft

ft

ft

Measured level, the same on every side

Checked against the minimum slopes in IRC 2021 Section R905

Roof pitch

6/12

26.57° · 50% grade

Code check: Asphalt shingles

Meets the minimum

6/12 against a 2/12 minimum (9.46°) · IRC R905.2.2

Rafter length

17 ft 10 5/8 in

17.89 ft · 15 ft run + 1 ft overhang

Ridge height

7 ft 6 in

15 ft run × 0.5

Roof area

1,503 sq ft

15.03 squares · 42 × 32 ft with overhang × 1.118

Pitch factor

× 1.118

Hip/valley factor 1.500

OSHA calls anything over 4 in 12 a steep roof (29 CFR 1926.500(b)); on one, employers must protect workers 6 ft or more above a lower level with guardrails and toeboards, safety nets or personal fall arrest (1926.501(b)(11)).

Roof cross-section

Cross-section of a gable roof: 15 ft run and 7.5 ft rise on each side, 17 ft 10 5/8 in rafters including the overhang, pitch 6/12.

Dashed: rafter tails over the eave overhang. Lengths are measured along one slope.

What the code allows at 6/12

Covering Minimum At your pitch
Standing-seam metal panels IRC R905.10.2 0.25/12 (1.19°) Allowed
Low-slope membrane (EPDM, TPO, PVC, mod-bit, built-up) IRC R905.9.1, R905.11.1–R905.15.1 0.25/12 (1.19°) Allowed
Lapped metal panels with lap sealant IRC R905.10.2 0.5/12 (2.39°) Allowed
Mineral-surfaced roll roofing IRC R905.5.2 1/12 (4.76°) Allowed
Asphalt shingles IRC R905.2.2 2/12 (9.46°) Allowed
Clay or concrete tile IRC R905.3.2 2.5/12 (11.77°) Allowed
Metal shingles IRC R905.4.2 3/12 (14.04°) Allowed
Lapped metal panels without sealant IRC R905.10.2 3/12 (14.04°) Allowed
Wood shingles IRC R905.7.2 3/12 (14.04°) Allowed
Wood shakes IRC R905.8.2 3/12 (14.04°) Allowed
Slate IRC R905.6.2 4/12 (18.43°) Allowed

Minimums from the 2021 International Residential Code, Section R905. Asphalt shingles from 2/12 to under 4/12 and clay or concrete tile from 2.5/12 to under 4/12 need two layers of underlayment. Your local code and the manufacturer's instructions can be stricter.

Roof pitch chart

Pitch Degrees Grade Factor Hip/valley
0.25/12 1.19° 2.1% 1.000 1.414
0.5/12 2.39° 4.2% 1.001 1.415
1/12 4.76° 8.3% 1.003 1.417
2/12 9.46° 16.7% 1.014 1.424
3/12 14.04° 25% 1.031 1.436
4/12 18.43° 33.3% 1.054 1.453
5/12 22.62° 41.7% 1.083 1.474
6/12 26.57° 50% 1.118 1.500
7/12 30.26° 58.3% 1.158 1.530
8/12 33.69° 66.7% 1.202 1.563
9/12 36.87° 75% 1.250 1.601
10/12 39.81° 83.3% 1.302 1.641
11/12 42.51° 91.7% 1.357 1.685
12/12 45° 100% 1.414 1.732
13/12 47.29° 108.3% 1.474 1.781
14/12 49.4° 116.7% 1.537 1.833
15/12 51.34° 125% 1.601 1.887
16/12 53.13° 133.3% 1.667 1.944
17/12 54.78° 141.7% 1.734 2.002
18/12 56.31° 150% 1.803 2.062
19/12 57.72° 158.3% 1.873 2.123
20/12 59.04° 166.7% 1.944 2.186
21/12 60.26° 175% 2.016 2.250
22/12 61.39° 183.3% 2.088 2.315
23/12 62.45° 191.7% 2.162 2.382
24/12 63.43° 200% 2.236 2.449

Factor: rafter length per unit of run. Hip/valley factor: hip or valley rafter length per unit of common-rafter run. The row nearest your pitch is highlighted.

How this is calculated

  1. Slope = rise ÷ run = 6 ÷ 12 = 0.5
  2. Run = half the width: 30 ft ÷ 2 = 15 ft
  3. Pitch factor = square root of (1 + 0.5²) = 1.118; hip/valley factor = square root of (2 + 0.5²) = 1.500
  4. Rafter = (15 ft + 1 ft) × 1.118 = 17.89 ft
  5. Ridge height = 15 ft × 0.5 = 7.5 ft
  6. Area = (40 ft + 2 × 1 ft) × (30 ft + 2 × 1 ft) × 1.118 = 1,503 sq ft
  7. One pitch on every plane: area = footprint × factor, whatever the shape.

Assumes one pitch on every roof plane and the same overhang on every side. Dormers, valleys and gambrel or mansard roofs need their own measurements.

Minimum slopes: 2021 International Residential Code, Section R905 (ICC). Steep-roof definition and fall protection: OSHA 29 CFR 1926.500(b) and 1926.501(b)(10)–(11).

Share

Roof pitch calculator. Pitch in x/12 and degrees, rafter length, roof area and code minimums.

The roof pitch calculator turns the rise you measure over 12 inches, or a ridge height or angle, into the pitch as x/12, degrees and percent grade. It also sizes the rafters and the roof area from the building footprint plus overhang, and checks the pitch against the IRC minimum for shingles, metal, tile, slate, wood and low-slope membranes.

What is roof pitch? Rise per foot of run, angle and grade

Roof pitch is the number of inches a roof rises for every 12 inches of horizontal run, written x/12: a 6/12 roof climbs 6 inches per foot of run, which is an angle of 26.57° and a 50% grade. The pitch card in the calculator shows all three forms at once, as 6/12 · 26.57° · 50% grade.
Converting between them starts with one division. Rise ÷ 12 gives the slope (6 ÷ 12 = 0.5); the grade is that slope as a percent (50%); the angle is the one whose tangent equals the slope (26.57°). A 12/12 roof is 45° because rise and run are equal. Going the other way, 30° works out to 6.93/12, and the card adds "Closest standard pitch: 7/12 (30.26°)" so the reading can be matched to a pitch chart.
Wikipedia's roof pitch article keeps a stricter distinction: pitch as the rise over the whole span, wall to wall, and slope as the rise over the run, half the span. In that sense a 6/12 roof has a 1/4 pitch. The IRC and this calculator both measure rise over run, which is the sense of "4/12 roof pitch" in a search or on a job site.
The building code and OSHA both key on pitch. IRC 2021 Section R905 sets a minimum for each roof covering, from 0.25/12 for standing-seam metal and most membranes (coal-tar built-up roofing goes down to 1/8 inch per foot) up to 4/12 for slate, with a band below 4/12 where asphalt shingles and clay or concrete tile need two layers of underlayment. OSHA calls any roof over 4 in 12 a steep roof. Employers must protect roofers working 6 ft or more above a lower level at any pitch, and on a steep roof the warning lines and safety monitors allowed on lower slopes stop counting: it takes guardrails with toeboards, safety nets or personal fall arrest. Pitch also sets how much roof covers a footprint: the pitch factor, the square root of (1 + slope²), is 1.118 at 6/12 and 1.414 at 12/12, so a 1,344 sq ft plan carries 1,503 or 1,901 sq ft of roof.
The fold "What the code allows at 6/12" lists every covering the calculator checks, sorted by minimum, with its IRC section and its status at your pitch, and highlights the row for the covering you picked.

Minimum roof pitch by covering, IRC 2021 Section R905

From this pitchAngleGradeCoverings the IRC addsSection
0.25/121.19°2.1%Standing-seam metal panels; low-slope membranes: built-up, modified bitumen, EPDM, TPO, PVC, spray foam, liquid-applied (coal-tar built-up from 1/8 in per foot)R905.10.2 item 3; R905.9.1, R905.11.1–R905.15.1
0.5/122.39°4.2%Lapped metal panels with applied lap sealantR905.10.2 item 2
1/124.76°8.3%Mineral-surfaced roll roofingR905.5.2
2/129.46°16.7%Asphalt shingles, with two layers of underlayment below 4/12R905.2.2, R905.1.1
2.5/1211.77°20.8%Clay or concrete tile, with two layers of underlayment below 4/12R905.3.2
3/1214.04°25%Metal shingles; lapped metal panels without sealant; wood shingles; wood shakesR905.4.2; R905.10.2 item 1; R905.7.2; R905.8.2
4/1218.43°33.3%Slate; asphalt shingles and tile no longer need the second underlayment layerR905.6.2
Over 4/12Over 18.43°Over 33.3%No new covering; OSHA classes the roof as a steep roof29 CFR 1926.500(b)

Using the calculator on one job: a 3/12 porch, shingles or standing-seam metal

A homeowner is re-roofing a covered porch: a shed roof that slopes away from the house wall, 9 ft from the wall to the drip edge and 22 ft end to end, both measured level. A 12-inch mark on a level held against the deck shows a 3-inch gap, and the choice is between asphalt shingles and standing-seam metal.
1. Slope. Leave Rise over run selected and type Rise 3, Run 12. The Roof pitch card reads 3/12 · 14.04° · 25% grade, and no OSHA line appears, since OSHA's steep-roof rule starts above 4 in 12.
2. Roof. Pick Shed (1 slope), set Width (across the ridge) to 9 and Length (along the ridge) to 22, and set Eave overhang to 0. Both sizes were taken to the drip edge, so they already include the eave, and the house side has no overhang at all; left at 1, the field would add a foot on every side.
3. Sizes. Rafter length shows 9 ft 3 3/8 in (9.28 ft), High side above low side shows 2 ft 3 in, and Roof area shows 204 sq ft, or 2.04 squares, from a 22 × 9 ft plan × 1.031. With the eave folded into the 9 ft, the 2 ft 3 in runs from the wall down to the drip edge; the wall ledger stands above the porch beam by 3 inches for each foot of level distance between them.
4. Shingles. With Asphalt shingles in Roof covering, the Code check card reads Allowed with two layers of underlayment, "3/12 is between 2/12 and 4/12 · IRC R905.2.2". Shingles are legal here over a doubled underlayment, and the shingle maker's low-slope instructions have to accept 3/12 as well.
5. Metal. Switch Roof covering to Standing-seam metal panels and the card reads Meets the minimum, "3/12 against a 0.25/12 minimum (1.19°) · IRC R905.10.2". Open "What the code allows at 3/12": every covering on the list passes except slate, which needs 4/12, and asphalt shingles and clay or concrete tile show Two layers of underlayment.
6. Share. Copy the address bar. The link reopens the same porch for the roofer who quotes it.
Both options pass the code at 3/12, and the difference the calculator shows is the underlayment; the decision then turns on price and on each product's installation instructions. Had the level shown 2 inches, the shingle verdict would sit at the bottom of the same two-layer band. At 1.5 inches it would read Below the minimum, and the note would list standing-seam metal among the four coverings still allowed.

How to measure roof pitch for each input method

The three method pills in the Slope block match three ways of getting the number. Measure from the attic or from a ladder at a gable end when you can.
Rise over run, with a level and a tape. In the attic, hold a level against the underside of a rafter with one end touching, center the bubble, and mark 12 inches along the level. The vertical distance from that mark up to the rafter is the rise; on the roof, the same reading runs from the mark down to the deck. Type it in Rise and keep Run at 12. A 24-inch level halves the effect of a bump in the deck: type the rise measured at 24 inches and set Run to 24, since the two fields only need the same unit.
Ridge height, with a tape in the attic or at a gable end. Measure from the top of the walls up to the ridge and type the width of the building. The calculator takes the run from the width: half of it on a gable, half the shorter side on a hip, and all of it on a shed, where the field is labeled High side above the low side.
Known pitch, from a gauge, an app or the plans. A phone inclinometer reads degrees, a pitch gauge reads degrees or x/12 depending on the model, a house plan may state x/12, and a site survey may give percent. Choose the form under Pitch written as and type the number.

Worked roof pitch examples: common pitches, a hip roof, a low slope and slate

One 30 × 40 ft house at 3/12, 4/12, 6/12, 8/12 and 12/12

The default house is a 30 × 40 ft gable with a 1 ft overhang, so its plan is 42 × 32 ft, or 1,344 sq ft. Each row is what the cards show with Known pitch and Asphalt shingles selected.
PitchAngleRidge heightRafterRoof areaAsphalt shinglesOSHA line
3/1214.04°3 ft 9 in16 ft 5 7/8 in1,385 sq ft (13.85 squares)Allowed with two layers of underlaymentNot shown
4/1218.43°5 ft 0 in16 ft 10 3/8 in1,417 sq ft (14.17 squares)Meets the minimumNot shown
6/1226.57°7 ft 6 in17 ft 10 5/8 in1,503 sq ft (15.03 squares)Meets the minimumShown
8/1233.69°10 ft 0 in19 ft 2 3/4 in1,615 sq ft (16.15 squares)Meets the minimumShown
12/1245°15 ft 0 in22 ft 7 1/2 in1,901 sq ft (19.01 squares)Meets the minimumShown
Going from 4/12 to 12/12 adds 484 sq ft of roof over the same plan, about a third more, and nearly 6 ft to each rafter. Two thresholds meet at 4/12: asphalt shingles leave the two-layer band there, and OSHA still counts the roof as low-slope, since its steep-roof line starts above 4 in 12.

A hip roof 40 ft wide and 30 ft long at 6/12

Choose Hip (4 slopes) and type Width 40 and Length 30. A line with the results explains the run: "A hip roof's ridge runs along the longer side, so the run is half the shorter side (30 ft): 15 ft." The common rafter is 17 ft 10 5/8 in, and the rafter card adds "Hip rafter: 24 ft 0 in", from the hip/valley factor of 1.500 instead of the pitch factor of 1.118.
The roof area is 1,503 sq ft (32 × 42 ft with overhang × 1.118), the same as a gable on that footprint. Hip ends add rafter length at the corners and no surface, as long as all four planes share one pitch.

An addition drawn at 1.5/12: what can go on it

Plans for a back addition list a 1.5/12 roof. Choose Known pitch, leave Pitch written as on Rise in 12 (x/12) and type 1.5. The pitch card reads 1.5/12 · 7.13° · 12.5% grade, with "Closest standard pitch: 2/12 (9.46°)".
With Asphalt shingles selected, the code card reads Below the minimum, "1.5/12 against a 2/12 minimum (9.46°) · IRC R905.2.2", and its note lists what the IRC does allow at that pitch: Standing-seam metal panels · Low-slope membrane (EPDM, TPO, PVC, mod-bit, built-up) · Lapped metal panels with lap sealant · Mineral-surfaced roll roofing. On the default 30 × 40 ft plan the roof area is 1,354 sq ft against a 1,344 sq ft plan, a factor of 1.008, so at this pitch the covering is the decision and the extra area is a rounding detail.

Slate on an existing 3/12 roof

Type 3 under Known pitch and pick Slate in Roof covering. The code card reads Below the minimum, "3/12 against a 4/12 minimum (18.43°) · IRC R905.6.2", and its note lists the other ten coverings, all of which the IRC allows at 3/12, including asphalt shingles, clay or concrete tile, metal shingles and wood shakes.
Slate needs the roof to reach 4/12. On the default 30 × 40 ft gable that lifts the ridge from 3 ft 9 in to 5 ft 0 in and the roof area from 1,385 to 1,417 sq ft, and getting there means reframing the roof.

Roof pitch formulas: angle, pitch factor, rafter length and roof area

p=riserunθ=arctan⁡pf=1+p2fh=2+p2p = \frac{\text{rise}}{\text{run}} \qquad \theta = \arctan p \qquad f = \sqrt{1 + p^{2}} \qquad f_{h} = \sqrt{2 + p^{2}}
  • pp = Slope: rise divided by run in the same unit, so 6 in over 12 in gives 0.5. The pitch in x/12 is 12 × p, and the grade is 100 × p percent.
  • θ\theta = Roof angle from horizontal: 26.57° at 6/12, 45° at 12/12.
  • ff = Pitch factor: rafter length per foot of run and roof area per square foot of plan, 1.118 at 6/12.
  • fhf_{h} = Hip/valley factor: hip or valley rafter length per foot of common-rafter run, 1.500 at 6/12.
  • RR = Run: half the width on a gable, half the shorter side on a hip, the full width on a shed.
  • oo = Eave overhang, measured level and counted on every side.
The slope p fixes the angle, the grade and both factors; the run R and the overhang o set the sizes. On a gable or a hip, the common rafter runs from the ridge to the end of the overhang and the hip rafter follows the hip/valley factor:
Lrafter=(R+o) fLhip=(R+o) fhHridge=R pL_{\text{rafter}} = (R + o)\,f \qquad L_{\text{hip}} = (R + o)\,f_{h} \qquad H_{\text{ridge}} = R\,p
On a shed the run is the full width and the rafter carries an overhang at both eaves, so its length is (width + 2 × overhang) × f. Roof area is the plan, overhang included, times the pitch factor:
A=(length+2o)(width+2o) fsquares=A100A = (\text{length} + 2o)(\text{width} + 2o)\,f \qquad \text{squares} = \frac{A}{100}
The area formula holds for a gable, a hip or a shed as long as every plane has the same pitch, because each square foot of plan carries f square feet of roof whatever the outline.
Worked on the default 30 × 40 ft gable at 6/12 with a 1 ft overhang: p = 0.5 and f = 1.118, the run is 15 ft, the rafter is (15 + 1) × 1.118 = 17.89 ft, which the card prints as 17 ft 10 5/8 in, and the ridge is 15 × 0.5 = 7.5 ft. The area is 42 × 32 × 1.118 = 1,503 sq ft, or 15.03 squares, and a hip rafter on the same run would be (15 + 1) × 1.500 = 24 ft.

Roof pitch mistakes that change the answer

  • Dividing the ridge height by the whole width. Rise over the full span gives half the slope: a 7.5 ft ridge over a 30 ft wide gable reads as 0.25, a 3/12, when the roof is a 6/12. The Ridge height method halves the width for a gable, so type the building width and let it find the run.
  • Reading the level over a bump or a shingle lap. A 1/4-inch error over a 12-inch level turns a true 4/12 into 3.75/12 or 4.25/12: the first fails slate's 4/12 minimum, the second prints the OSHA steep-roof line. Over a 24-inch level the same error costs half as much; type the rise at 24 inches with Run set to 24.
  • Leaving the overhang out of the roof area. The default 30 × 40 ft gable at 6/12 has 1,503 sq ft of roof with a 1 ft overhang and 1,342 sq ft with none, 161 sq ft apart. Measure it level from the wall to the fascia; the field's helper reads "Measured level, the same on every side".
  • Using the common-rafter factor for a hip or valley rafter. At 6/12 the pitch factor is 1.118 and the hip/valley factor 1.500. On a 15 ft run with a 1 ft overhang that is a 17 ft 10 5/8 in common rafter against a 24 ft 0 in hip rafter.
  • Taking the IBC or a product sheet for the house code. Wood shakes need 3/12 under IRC R905.8.2 and 4/12 under the IBC, and a shingle maker can set its own floor above the IRC's 2/12. Check the IRC minimum here, then read the product's installation instructions before ordering.
  • Typing an angle into the x/12 field. A gauge reading of 26.57 typed into the Pitch field that ends in /12 describes a roof of almost 66°. Choose Degrees (°) under Pitch written as, then type 26.57 again in the Angle field, and the card reads 6/12. Switching the select alone keeps the roof already entered, so the Angle field first shows 65.69.

Limits of the pitch, area and code check

The calculator models a roof with one pitch on every plane and the same level overhang on every side. That fits gable, hip and shed roofs, and the area of any footprint that keeps one pitch. These fall outside it:
  • dormers, valleys, crickets and two-pitch roofs such as gambrel and mansard, which need each plane measured on its own;
  • waste, starter and ridge-cap allowances, shingle bundles and underlayment rolls, since the area is roof surface in square feet and squares;
  • cost, snow load and wind design;
  • rafter cut angles such as plumb cuts, seat cuts and birdsmouth layout;
  • metric input, which the US version does not take.
The code check compares your pitch with the minimum slopes in IRC 2021 Section R905, which the 2024 edition keeps unchanged. Local amendments and the covering's installation instructions can be stricter, as the caption under the code table says, and the IBC that governs other buildings is not part of the check. The OSHA line restates 29 CFR 1926.500(b) and 1926.501(b)(11), which bind employers; it classifies the roof and does not rate it as safe or unsafe to climb.

Roof pitch questions: angles, minimums by roofing and sizing

What angle is a 4/12 roof pitch?

A 4/12 roof pitch is 18.43°, a 33.3% grade: the roof rises 4 inches for every 12 inches of run. It is the lowest pitch the IRC accepts for slate, the point where asphalt shingles drop the second underlayment layer, and the last pitch OSHA calls low-slope.

How steep is a 6/12 roof pitch?

A 6/12 pitch is 26.57°, a 50% grade, with a pitch factor of 1.118. On a 30 × 40 ft house with a 1 ft overhang it gives a 7 ft 6 in ridge, 17 ft 10 5/8 in rafters and 1,503 sq ft of roof, and it is past OSHA's steep-roof line of 4 in 12.

What is a 12/12 roof pitch in degrees?

A 12/12 roof pitch is 45°, a 100% grade, because the rise equals the run. Its pitch factor is 1.414, so each square foot of plan carries 1.414 sq ft of roof, and its hip/valley factor is 1.732. Under OSHA it is a steep roof.

How do I convert roof pitch to degrees?

Divide the rise by 12 and take the arctangent: 4/12 is the arctangent of 0.333, or 18.43°, 8/12 is 33.69° and 12/12 is 45°. In reverse, multiply the tangent of the angle by 12, so 30° is 6.93/12. In the calculator, choose Known pitch and pick Degrees (°) or Rise in 12 (x/12) under Pitch written as; the pitch card shows the x/12 value with the degrees and grade beneath it. The Roof pitch chart fold lists 0.25/12 to 24/12 with degrees, grade and both factors.

Is roof pitch the same as roof slope?

Bob Vila's roof pitch guide notes that the two words are often used interchangeably for the rise per 12 inches of run, and that is what a search for "4/12 roof pitch" means. The stricter carpentry sense, kept by Wikipedia's roof pitch article and by the same guide, makes pitch the rise over the whole span and slope the rise over the run, so a 6/12 slope is a 1/4 pitch. The IRC states its minimums as rise over run, and so does this calculator.

What is the most common roof pitch for a house?

Published guides answer with a band. This Old House's article puts most homes between 4/12 and 8/12 in its body text and between 4/12 and 9/12 in its own FAQ, and Omni gives 4/12 to 9/12. Across that band the angle runs from 18.43° to 36.87° and the pitch factor from 1.054 to 1.250, so a footprint carries 5% to 25% more roof than its plan.

What is the minimum roof pitch for asphalt shingles?

The IRC sets 2/12 (9.46°) in Section R905.2.2, and from 2/12 up to 4/12 it requires two layers of underlayment (R905.1.1). Below 2/12 the code does not allow asphalt shingles whatever the underlayment. Shingle makers set their own bar for a standard installation: IKO's guide on shingle slope calls 2/12 the traditional absolute minimum and 4/12 generally the lowest slope for a standard install, with special underlayment in between. Pick Asphalt shingles in Roof covering and the code card gives the verdict at your pitch; below 2/12 its note lists what can go on instead.

What is the minimum pitch for a metal roof?

It depends on the panel. Under IRC R905.10.2, standing-seam panels go down to 0.25/12 (1.19°), lapped panels with applied lap sealant to 0.5/12 (2.39°), and lapped panels without sealant need 3/12 (14.04°). Metal shingles need 3/12 under R905.4.2. Exposed-fastener corrugated and ribbed panels lap at the seams, so they fall in the lapped group: 3/12 as installed, 0.5/12 with lap sealant. The panel maker's installation guide can set a higher minimum.

What is the minimum pitch for a porch roof?

The IRC sets its minimums by roof covering, and a porch roof follows the same table as the house. Asphalt shingles need 2/12, with two layers of underlayment below 4/12; clay or concrete tile needs 2.5/12, metal shingles 3/12, roll roofing 1/12 and standing-seam metal 0.25/12. A porch read at 3 inches over a 12-inch level is a 3/12, where the calculator passes standing-seam metal outright and asphalt shingles with two layers of underlayment.

What is the minimum slope for a flat roof?

A roof built as flat still needs slope to drain. IRC R905 sets 0.25/12, a quarter inch per foot (1.19°, a 2.1% grade), for standing-seam metal and for membranes such as EPDM, TPO, PVC, modified bitumen and built-up roofing. The one lower figure is in R905.9.1, which lets coal-tar built-up roofs go to 1/8 inch per foot; the calculator applies 0.25/12 to the whole membrane group. Typed as 0/12, the code card reads Below the minimum and its note says nothing on the list is allowed. Omni's roof pitch page gives 0.5/12 as the smallest pitch of a roof, which is above the IRC floor for these systems.

Do wood shakes need a 3/12 or a 4/12 roof pitch?

On a house built under the IRC, wood shakes need 3/12 (14.04°) per Section R905.8.2, the same as wood shingles under R905.7.2. The 4/12 figure comes from the IBC, the code for buildings outside the residential code: roofonline's minimum-pitch table lists wood shakes at 4-in-12 because its values follow the IBC. The code your jurisdiction adopted for the building decides which applies.

What roof pitch is too steep to walk on?

OSHA draws its line at 4 in 12. A roof steeper than that is a steep roof under 29 CFR 1926.500(b), and employers must protect workers 6 ft or more above a lower level on it with guardrails and toeboards, safety nets or personal fall arrest (1926.501(b)(11)). For roofing work at 4 in 12 or less, a warning line combined with one of those systems or with a safety monitor is also allowed (1926.501(b)(10)). The calculator prints the steep-roof line for any pitch over 4/12. The rule binds employers and leaves a homeowner working on their own roof outside its scope; it remains the federal definition of a steep roof.

How do I find roof pitch from the ridge height?

Divide the ridge height by the run and multiply by 12. On a gable the run is half the building width, so a ridge 7.5 ft above the top of the walls on a 30 ft wide house gives 7.5 ÷ 15 = 0.5, a 6/12 pitch. Choose the Ridge height method in the Slope block, type the height and the width, and the calculator takes half the width on a gable, half the shorter side on a hip and the full width on a shed.

What is a roof pitch multiplier?

The roof pitch multiplier, or pitch factor, is the square root of (1 + (rise ÷ 12)²). It turns run into rafter length and plan area into roof area: 1.054 at 4/12, 1.118 at 6/12 and 1.414 at 12/12. The hip/valley factor, the square root of (2 + (rise ÷ 12)²), does the same for hip and valley rafters.

How much does roof pitch add to the roof area?

Multiply the plan, overhang included, by the pitch factor. The default 30 × 40 ft house with a 1 ft overhang has a 42 × 32 ft plan of 1,344 sq ft; at 6/12 the factor of 1.118 makes that 1,503 sq ft, or 15.03 squares of 100 sq ft. Leave the overhang out and the figure drops to 1,342 sq ft. calculator.net's roofing calculator takes the house base area and an eaves stick-out without saying how it spreads the overhang around that area; the Roof area card here prints the plan it used, 42 × 32 ft with overhang × 1.118.

My pitch is below the minimum for the roofing I want. What are my options?

Read the note under the code card: it lists the coverings the IRC allows at your pitch. At 1.5/12 it names standing-seam metal panels, low-slope membranes, lapped metal panels with lap sealant and mineral-surfaced roll roofing. The other route is reframing until the pitch reaches the covering's minimum; on the default 30 × 40 ft gable, going from 3/12 to slate's 4/12 lifts the ridge from 3 ft 9 in to 5 ft 0 in. Reframing is structural work, so ask your building department what it requires before planning it.

What does "Allowed with two layers of underlayment" mean?

Your pitch clears the covering's minimum but sits below 4/12, the band where the IRC requires a double layer of underlayment: 2/12 up to 4/12 for asphalt shingles (R905.1.1 and R905.2.2) and 2.5/12 up to 4/12 for clay or concrete tile (R905.3.2). Mention it when you ask for quotes, since the second layer is extra material and labor, and check the shingle or tile maker's low-slope instructions, which can ask for more.

Why does the pitch card show a closest standard pitch?

A reading 0.05 or more away from a whole pitch gets a note naming the nearest one (below 1/12, the nearest eighth), so it can be matched to a pitch chart or a plan. Typing 4.8/12 shows 21.8° and 40% with "Closest standard pitch: 5/12 (22.62°)". The note changes no result: the code check, the rafter and the area all use 4.8/12.

How exact are the rafter length and roof area?

Rafter length shows to the nearest 1/8 inch with decimal feet beside it, the area to the nearest square foot and the squares to two decimals; the values behind them are not rounded. The exceptions are the code check and the OSHA line, which compare the pitch at the two decimals the card shows, so 9.46° counts as 2/12. The model sets the limits: one pitch on every plane and the same overhang on every side, with no allowance for waste, dormers or valleys.

Can I send this roof to a roofer?

Yes. The address bar carries every input you changed from the defaults, so a copied link reopens the same roof: ?method=pitch&per12=4.8 brings back a 4.8/12 pitch and ?covering=slate the slate check. A link with nothing after the page address opens the default 30 × 40 ft gable at 6/12 with asphalt shingles.

Sources & References

  1. International Code Council, 2021 International Residential Code, Section R905 — minimum slopes by roof covering: asphalt shingles 2:12, with double underlayment from 2:12 up to 4:12 (R905.2.2); clay or concrete tile 2.5:12, likewise doubled up to 4:12 (R905.3.2); metal shingles, wood shingles, wood shakes and lapped metal panels 3:12; slate 4:12; mineral-surfaced roll roofing 1:12; lapped metal panels with lap sealant 0.5:12; standing-seam metal and low-slope membranes 0.25:12
  2. Occupational Safety and Health Administration, 29 CFR 1926.500(b), definitions for fall protection in construction — a low-slope roof has a slope of 4 in 12 or less; a steep roof has a slope greater than 4 in 12
  3. Occupational Safety and Health Administration, 29 CFR 1926.501(b)(10)–(11) — with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, roofers on a low-slope roof need guardrails, safety nets, personal fall arrest, or a warning line combined with one of these or with a safety monitor; on a steep roof, guardrails with toeboards, safety nets or personal fall arrest

Content verified by the Smart Calculators Team